Design guide
How to Size a Box Gutter to BS EN 12056-3
Quick answer
To size a box gutter, work out the flow it must carry (design rainfall intensity × effective roof area), then choose a gutter cross-section and number of outlets whose capacity exceeds that flow, with freeboard and overflows. In the UK this is done to BS EN 12056-3 and its UK National Annex. CGL carries out these gravity drainage calculations free of charge.
Let us do the maths
Gutter sizing should always be confirmed by a qualified designer. CGL carries out gravity drainage calculations in-house, free of charge, and works with West Siphonics where siphonic drainage is needed. Just send us your roof drawings.
Step 1: Choose the design rainfall intensity
Rainfall intensity is taken from the UK National Annex to BS EN 12056-3 for the building's location, using a return period based on how serious an overflow would be.
Rainfall intensity (r) is expressed in litres per second per m² (l/s/m²). The more serious the consequence of the gutter overflowing, the longer the return period and the higher the design intensity. An eaves gutter that spills outside is lower risk than a valley gutter over a warehouse full of stock, or a building where water ingress is unacceptable (such as a hospital, data centre or museum). Box and valley gutters inside the building line are normally designed to a higher risk category than eaves gutters.
Step 2: Calculate the effective roof area
The effective roof area (A) is the plan area of roof draining to the gutter, increased for sloping roofs to allow for wind-driven rain.
For a pitched roof, BS EN 12056-3 adds an allowance for rain driven onto the slope by wind:
A = LR × (BR + HR ÷ 2)
where LR is the length of the gutter, BR the horizontal width of the roof slope, and HR the vertical height from gutter to ridge. Walls that shed water onto the roof also add to the area.
Step 3: Work out the flow rate
Q = r × A × C
where Q is the flow (l/s), r the rainfall intensity (l/s/m²), A the effective area (m²), and C a runoff coefficient, which is taken as 1.0 for profiled-metal industrial roofs (all the rain reaches the gutter).
Step 4: Check the gutter capacity
The gutter's capacity depends on its cross-section, the depth of water it can carry, its length and the outlets.
- Cross-section: wider and deeper gutters carry more. Box gutters must also keep a freeboard, a margin of empty depth between the design water level and the top of the gutter.
- Length: BS EN 12056-3 treats a gutter as "long" when its length is more than 50 times the design water depth. Long gutters lose capacity to friction, so a reduction factor applies.
- Fall: most box gutters are laid level or near-level; the standard covers both.
- Bends: angles in the gutter reduce capacity and need to be allowed for.
Step 5: Size and space the outlets
Outlets often limit capacity more than the gutter does.
Each outlet has a maximum flow based on its diameter and the depth of water above it. Adding a sump increases the water depth over the outlet and so its capacity. Spacing outlets more closely shortens each gutter run and reduces the flow each run has to carry. On very large roofs, a siphonic drainage system can drain the same area with far fewer downpipes.
Step 6: Design the overflows
Box and valley gutters need overflows (usually weirs through the parapet or at gutter ends) sized to discharge water safely if an outlet blocks. Overflows should be positioned so a blockage is visible from outside, alerting building managers before damage occurs.
Worked example: warehouse valley gutter
A simplified example to show the method. The figures are illustrative only; use the National Annex values for your site.
| Input | Value |
|---|---|
| Gutter length | 60 m |
| Roof slopes draining in | 2 × 12 m horizontal width |
| Height gutter to ridge | 1.2 m each side |
| Design rainfall intensity (example) | 0.040 l/s/m² |
| Effective area | 60 × 2 × (12 + 1.2 ÷ 2) = 1,512 m² |
| Design flow Q | 0.040 × 1,512 × 1.0 ≈ 60.5 l/s |
The designer then checks gutter cross-sections, outlet numbers and sump sizes until the system carries at least 60.5 l/s with the required freeboard, and sizes overflows for a blocked outlet.
Common sizing mistakes
- Using the plan area only and ignoring the slope and wind allowance
- Using an eaves-gutter risk category for an internal valley gutter
- Assuming the outlet can take the full gutter flow without a sump
- Forgetting the long-gutter reduction on long runs
- Leaving out overflows or putting them where blockages go unnoticed
- Re-lining an old gutter without checking it was big enough in the first place
Frequently asked questions
What British Standard covers gutter sizing?
BS EN 12056-3 (Gravity drainage systems inside buildings: Roof drainage, layout and calculation) together with its UK National Annex. It covers rainfall intensity, effective roof area, gutter and outlet capacity, and overflows.
How do you calculate gutter capacity?
Calculate the flow the gutter must carry (rainfall intensity × effective roof area × runoff coefficient). Then check that the gutter's cross-section, length, outlets and sumps can carry that flow while keeping the required freeboard. BS EN 12056-3 gives the method.
What rainfall intensity is used in the UK?
It depends on the location and the risk category of the gutter. The UK National Annex to BS EN 12056-3 gives rainfall intensities for different return periods across the country. Internal box and valley gutters are designed to more severe values than eaves gutters.
How many outlets does a box gutter need?
Enough that the total outlet capacity exceeds the design flow and no gutter run is too long. Outlet capacity depends on diameter and water depth, so adding sumps or more outlets can reduce the gutter size needed.
Does CGL size gutters for free?
Yes. CGL carries out gravity-fed drainage calculations in-house free of charge. Where siphonic drainage is needed, calculations are done in partnership with West Siphonics.
Free gutter drainage calculations
CGL designs and manufactures industrial and commercial gutter systems and carries out gravity drainage calculations in-house, free of charge. Send us your roof drawings and we'll size the gutter, outlets and overflows for you.
Get in touch Download area